Medical Physics - exam practice
Medical Physics
Question 1 of 10
1 of 10
A radiographer in a hospital directs a parallel beam of X-rays at the leg bone of a patient. The attenuation (absorption) coefficient of bone is 0.7 cm-1.
The answers below are given to one significant figure.
What is the percentage intensity of X-rays transmitted through bone of thickness 9.7 cm?
Question 2 of 10
2 of 10
The Doppler effect is used to measure the speed of blood flow in arteries.
What medical diagnostic method uses this technique?
Question 3 of 10
3 of 10
Ultrasound is reflected at a boundary between two materials.
Which property of the materials governs the intensity of the ultrasound reflected at the boundary?
Question 4 of 10
4 of 10
A contrast material is used while taking an X-ray image of a patient.
Which statement is correct?
Question 5 of 10
5 of 10
There are four important attenuation mechanisms by which X-ray photons may interact when they pass through matter.
In which mechanism is the X-ray photon scattered with a longer wavelength?
Question 6 of 10
6 of 10
The acoustic impedance Z of a material in the shape of a cube can be determined using the equation
Where M is the mass of the material, L is the length of each side of the cube and c is the speed of ultrasound in the material.
The percentage uncertainty in L is 1.2 % and the percentage uncertainty in c is 1.8 %. The percentage uncertainty in M is negligible.
What is the percentage uncertainty in Z?
Question 7 of 10
7 of 10
The potential difference across the cathode and anode of an X-ray tube is V. The minimum wavelength of the X-ray photons emitted from the tube is .
Which of the following statements is / are correct?
- is halved when V is doubled.
- is unchanged when the temperature of the cathode is increased.
- is independent of the cathode material.
Question 8 of 10
8 of 10
Which is not a component used in a gamma camera?
Question 9 of 10
9 of 10
A beam of ultrasound is incident normally at a boundary between two tissues F and G.
The table shows some data on the two tissues.
| Tissue F | Tissue G | |
|---|---|---|
| Density of tissue | 1.2 | |
| Speed of ultrasound in tissue | c | 1.5c |
What percentage of the intensity of the ultrasound is reflected at the boundary?
Question 10 of 10
10 of 10
What is the SI unit for acoustic impedance?